It is essential to thoroughly review the description prior to downloading the software.
The Odrid HMI serves as an operator panel tailored for various industrial control systems, facilitating communication via Wi-Fi or mobile internet. It utilizes protocols such as Modbus/TCP (Class 0 and 1), Modbus RTU Class 1, and Siemens S7 Communication (ISO-on-TCP).
This application provides a viable alternative to conventional SCADA systems and operator panels. It supports a diverse array of data types and features intuitive navigation between pages, enabled by swipe gestures or buttons, enhancing user experience.
Furthermore, Odrid HMI is well-suited for home automation, allowing users to control and monitor various systems including lighting, ventilation, and heating remotely through PLCs that implement the Modbus/TCP protocol.
- Technical Support: Excellent assistance is available.
- Updates: Regular updates are offered free of charge.
- Fast Development: Users can create graphic HMIs with multi-touch functionality in just minutes.
- Development Tools: A no-cost development tool featuring a test run capability is included.
- Scalability: There is virtually no limit on the number of pages, objects, or variables.
- Independence: No reliance on third-party services is required.
- Native Performance: It operates as a genuine native app.
The application boasts several notable features:
- Configurable communication parameters such as IP address and port number on a per-page basis.
- Automatic monitoring of all variables on the current page negates the need for a separate tag list.
- Diverse formats for numeric variables including various integer types, float (IEEE 754), and more.
- Event-driven communication prioritization ensures efficient data transfer to the controller.
- Edit pages using Density Independent Pixels (dp) for precise display on diverse devices.
- A life bit feature monitors the operator panel within the controller, akin to coordination areas found in Siemens S7 systems.
- Narrative representation of numeric variables through predefined text for elements such as alarms and sequence steps enhances clarity.
- Comprehensive diagnostics are available for connection and communication issues.
- The system allows for distinct areas dedicated to system variables, local variables, and constants.
- An automatic return feature resets the display to the start page after a defined period of inactivity.
- The facility to select high and low word order for 32-bit variables within the Modbus protocol is provided.
- Polling intervals can be adjusted to optimize data traffic or conserve battery life.
- A wide range of character set support includes Baltic, Central European, Chinese, Cyrillic, Eastern European, Greek, Hebrew, Japanese, Turkish, Vietnamese, and Western scripts.
- A test-run capability for pages is available within the development tool.
- LED representations can be customized in size, making them suitable for applications such as Andon systems.
- The option to select background colors for pages adds personalization.
- The Modbus Device ID can be modified via GUI elements during runtime.
- The app supports image buttons, password fields, floating-point formatting, and timestamping for page files.
- Hyperlinks facilitate easy navigation between documents embedded in page files.
The software’s implementation of protocols includes:
- Modbus/TCP: Class 0 (Function 3 and 16) permits reading and writing of up to 64,512 holding registers.
- Modbus/TCP: Class 1 (Function 1, 2, 4, and 5) allows reading up to 65,535 discrete inputs and output coils while also managing input registers.
- Modbus RTU: Supports both Class 0 and Class 1 protocols.
- Siemens S7 Communication: Enables reading from and writing to various memory areas covering up to 8192 bytes in DataBlock 1 through to address 4095 (with a default maximum DataBlock value set at 255).
The development tool provided for creating pages compatible with Odrid HMI can be accessed at: Download here.
User manual can be found at: Manual link.
A history of version updates is available at: Version history link.
Please note that Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc., while S7 and STEP 7 are trademarks of Siemens AG.
– Áttekintés
Odrid HMI Commercial szoftvere a kategória Üzlet fejlett mellett Jan Almqvist-ban.
A legutolsó változat-ból Odrid HMI a(z) 1.7.10, 2025. 01. 05. megjelent. Kezdetben volt hozzá, hogy az adatbázisunkban a 2025. 01. 05..
a(z) Odrid HMI a következő operációs rendszereken fut: iOS.
Felhasználók Odrid HMI 5 ki 5 csillagos minősítést adott neki.
2025. 01. 10. | S3 Explorer 1.4.3 |
2025. 01. 10. | Video Invite 2.0 |
2025. 01. 10. | Approach Kiosk 1.1.37 |
2025. 01. 10. | Kane Forest Notify 5.16.0 |
2025. 01. 10. | Saint Andrew's Episcopal 9.7 |
App Store
az ingyenes UpdateStar-ral.
Legutóbbi visszajelzések
Mobile Broadband HL Service
Maradjon kapcsolatban útközben a mobil szélessávú HL szolgáltatással |
|
User Experience Improvement Program Service
Fokozza felhasználói élményét az Acer Fejlesztési Program szolgáltatásával |
|
Microsoft SQL Server Compact x64 ENU
Hatékony SQL Server Compact x64 rendszerekhez |
|
App Explorer
Fedezze fel az alkalmazások világát a SweetLabs App Explorer segítségével. |
|
HP System Event Utility
HP rendszeresemény-segédprogram: A rendszeresemények kezelésének egyszerűsítése |
|
utools
Növelje termelékenységét az uTools segítségével! |