The Odrid HMI serves as an operator panel tailored for various industrial control systems, facilitating communication via Wi-Fi or mobile internet. It utilizes protocols such as Modbus/TCP (Class 0 and 1), Modbus RTU Class 1, and Siemens S7 Communication (ISO-on-TCP).

This application provides a viable alternative to conventional SCADA systems and operator panels. It supports a diverse array of data types and features intuitive navigation between pages, enabled by swipe gestures or buttons, enhancing user experience.

Furthermore, Odrid HMI is well-suited for home automation, allowing users to control and monitor various systems including lighting, ventilation, and heating remotely through PLCs that implement the Modbus/TCP protocol.

  • Technical Support: Excellent assistance is available.
  • Updates: Regular updates are offered free of charge.
  • Fast Development: Users can create graphic HMIs with multi-touch functionality in just minutes.
  • Development Tools: A no-cost development tool featuring a test run capability is included.
  • Scalability: There is virtually no limit on the number of pages, objects, or variables.
  • Independence: No reliance on third-party services is required.
  • Native Performance: It operates as a genuine native app.

The application boasts several notable features:

  • Configurable communication parameters such as IP address and port number on a per-page basis.
  • Automatic monitoring of all variables on the current page negates the need for a separate tag list.
  • Diverse formats for numeric variables including various integer types, float (IEEE 754), and more.
  • Event-driven communication prioritization ensures efficient data transfer to the controller.
  • Edit pages using Density Independent Pixels (dp) for precise display on diverse devices.
  • A life bit feature monitors the operator panel within the controller, akin to coordination areas found in Siemens S7 systems.
  • Narrative representation of numeric variables through predefined text for elements such as alarms and sequence steps enhances clarity.
  • Comprehensive diagnostics are available for connection and communication issues.
  • The system allows for distinct areas dedicated to system variables, local variables, and constants.
  • An automatic return feature resets the display to the start page after a defined period of inactivity.
  • The facility to select high and low word order for 32-bit variables within the Modbus protocol is provided.
  • Polling intervals can be adjusted to optimize data traffic or conserve battery life.
  • A wide range of character set support includes Baltic, Central European, Chinese, Cyrillic, Eastern European, Greek, Hebrew, Japanese, Turkish, Vietnamese, and Western scripts.
  • A test-run capability for pages is available within the development tool.
  • LED representations can be customized in size, making them suitable for applications such as Andon systems.
  • The option to select background colors for pages adds personalization.
  • The Modbus Device ID can be modified via GUI elements during runtime.
  • The app supports image buttons, password fields, floating-point formatting, and timestamping for page files.
  • Hyperlinks facilitate easy navigation between documents embedded in page files.

The software’s implementation of protocols includes:

  • Modbus/TCP: Class 0 (Function 3 and 16) permits reading and writing of up to 64,512 holding registers.
  • Modbus/TCP: Class 1 (Function 1, 2, 4, and 5) allows reading up to 65,535 discrete inputs and output coils while also managing input registers.
  • Modbus RTU: Supports both Class 0 and Class 1 protocols.
  • Siemens S7 Communication: Enables reading from and writing to various memory areas covering up to 8192 bytes in DataBlock 1 through to address 4095 (with a default maximum DataBlock value set at 255).

The development tool provided for creating pages compatible with Odrid HMI can be accessed at: Download here.

User manual can be found at: Manual link.

A history of version updates is available at: Version history link.

Please note that Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc., while S7 and STEP 7 are trademarks of Siemens AG.

Overzicht

Odrid HMI is Commercial software in de categorie Business ontwikkeld door Jan Almqvist.

De nieuwste versie van Odrid HMI is 1.7.10, uitgegeven op 05-01-2025. Het werd aanvankelijk toegevoegd aan onze database op 05-01-2025.

Odrid HMI draait op de volgende operating systems: iOS.

Gebruikers van Odrid HMI gaven het een beoordeling van 5 op 5 sterren.

Aanverwante producten


Veilige en gratis downloads, gecontroleerd door UpdateStar

Nu kopen
App Store
Blijf actueel
met UpdateStar freeware.

Recente beoordelingen

Antechinus Animator Antechinus Animator
Antechinus Animator: een gebruiksvriendelijke animatietool
DipTrace DipTrace
DipTrace: een veelzijdige PCB-ontwerptool
Chameleon Startup Manager Chameleon Startup Manager
Beheer moeiteloos uw opstartprogramma's met Chameleon Startup Manager
BCGControlBar Library Professional Edition BCGControlBar Library Professional Edition
Til uw MFC-toepassingen naar een hoger niveau met BCGControlBar Library Professional Edition
Elcomsoft Phone Breaker Elcomsoft Phone Breaker
Elcomsoft Phone Breaker: ontrafel de geheimen van mobiele data
Wise Data Recovery Wise Data Recovery
Efficiënte tool voor gegevensherstel voor eenvoudig bestandsherstel
Huidige nieuwsbrief