It is essential to thoroughly review the description prior to downloading the software.
The Odrid HMI serves as an operator panel tailored for various industrial control systems, facilitating communication via Wi-Fi or mobile internet. It utilizes protocols such as Modbus/TCP (Class 0 and 1), Modbus RTU Class 1, and Siemens S7 Communication (ISO-on-TCP).
This application provides a viable alternative to conventional SCADA systems and operator panels. It supports a diverse array of data types and features intuitive navigation between pages, enabled by swipe gestures or buttons, enhancing user experience.
Furthermore, Odrid HMI is well-suited for home automation, allowing users to control and monitor various systems including lighting, ventilation, and heating remotely through PLCs that implement the Modbus/TCP protocol.
- Technical Support: Excellent assistance is available.
- Updates: Regular updates are offered free of charge.
- Fast Development: Users can create graphic HMIs with multi-touch functionality in just minutes.
- Development Tools: A no-cost development tool featuring a test run capability is included.
- Scalability: There is virtually no limit on the number of pages, objects, or variables.
- Independence: No reliance on third-party services is required.
- Native Performance: It operates as a genuine native app.
The application boasts several notable features:
- Configurable communication parameters such as IP address and port number on a per-page basis.
- Automatic monitoring of all variables on the current page negates the need for a separate tag list.
- Diverse formats for numeric variables including various integer types, float (IEEE 754), and more.
- Event-driven communication prioritization ensures efficient data transfer to the controller.
- Edit pages using Density Independent Pixels (dp) for precise display on diverse devices.
- A life bit feature monitors the operator panel within the controller, akin to coordination areas found in Siemens S7 systems.
- Narrative representation of numeric variables through predefined text for elements such as alarms and sequence steps enhances clarity.
- Comprehensive diagnostics are available for connection and communication issues.
- The system allows for distinct areas dedicated to system variables, local variables, and constants.
- An automatic return feature resets the display to the start page after a defined period of inactivity.
- The facility to select high and low word order for 32-bit variables within the Modbus protocol is provided.
- Polling intervals can be adjusted to optimize data traffic or conserve battery life.
- A wide range of character set support includes Baltic, Central European, Chinese, Cyrillic, Eastern European, Greek, Hebrew, Japanese, Turkish, Vietnamese, and Western scripts.
- A test-run capability for pages is available within the development tool.
- LED representations can be customized in size, making them suitable for applications such as Andon systems.
- The option to select background colors for pages adds personalization.
- The Modbus Device ID can be modified via GUI elements during runtime.
- The app supports image buttons, password fields, floating-point formatting, and timestamping for page files.
- Hyperlinks facilitate easy navigation between documents embedded in page files.
The software’s implementation of protocols includes:
- Modbus/TCP: Class 0 (Function 3 and 16) permits reading and writing of up to 64,512 holding registers.
- Modbus/TCP: Class 1 (Function 1, 2, 4, and 5) allows reading up to 65,535 discrete inputs and output coils while also managing input registers.
- Modbus RTU: Supports both Class 0 and Class 1 protocols.
- Siemens S7 Communication: Enables reading from and writing to various memory areas covering up to 8192 bytes in DataBlock 1 through to address 4095 (with a default maximum DataBlock value set at 255).
The development tool provided for creating pages compatible with Odrid HMI can be accessed at: Download here.
User manual can be found at: Manual link.
A history of version updates is available at: Version history link.
Please note that Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc., while S7 and STEP 7 are trademarks of Siemens AG.
Overview
Odrid HMI is a Commercial software in the category Business developed by Jan Almqvist.
The latest version of Odrid HMI is 1.7.10, released on 01/05/2025. It was initially added to our database on 01/05/2025.
Odrid HMI runs on the following operating systems: iOS.
Users of Odrid HMI gave it a rating of 5 out of 5 stars.
01/24/2025 | Open TV 1.3.1 |
01/24/2025 | Microsoft - af-za 16.0.18324.20194 |
01/24/2025 | MegaLab 8.0.0.126 |
01/24/2025 | QC Unlocker Tool 2 |
01/24/2025 | CyberLink Holiday Pack 2012 Holiday Pack 4 2012 |
App Store
with UpdateStar freeware.
01/24/2025 | Vivaldi 7.1 with improved dashboard available |
01/22/2025 | VeraCrypt 1.26.18 available |
01/22/2025 | Oracle January 2025 Patch Update available |
01/16/2025 | Adobe January 2025 Patch Day |
01/15/2025 | Google Chrome 132 update available |
Latest Reviews
Dell Bluetooth-Software
Enhanced Connectivity with Dell Bluetooth Software |
|
OWOer
OWOer: A Unique Tool for Boosting Online Content Engagement |
|
UMTS USB Modem Manager
Seamless Connection with UMTS USB Modem Manager |
|
OWNU: Strength & Gym Training
Transform Your Workout with OWNU: Strength & Gym Training |
|
Schattenkopieclient
Schattenkopieclient: Effortless Backup Restoration |
|
docuPrinter LT
Effortless Document Conversion with docuPrinter LT |